Hot Runner Controls

Hot Runner Control Systems

Hot Runner Controls by DT Heaters & Controls include up to 24 temperature loops or 6 Valve Gate controls per mainframe cabinet.  Our control modules are compatible with Athena, DME, PCS, Yudo & Incoe hot runner systems.

 

Hot Runner Temperature Control Modules (Single-zone). Click the add to cart button below to purchase a Hot Runner Temperature Control Module, for your existing Yudo, Athena, DME, PCS, Incoe control system.

 

We offer Hot Runner control modules in either single or dual channel in either ready to use configurations or custom built to your specifications.  The Hot Runner controller modules can be purchased individually or packaged into a complete Hot Runner Controller system with up to 24 zones in a single system.

 

PNNameDescription Unit Price(USD)






DTHRC-B1Bench Top Single zone hot runner temperature controller1) Power Supply: 220Vac (or 230Vac), 1Phase 4-wire, 50-60Hz
2) 1pcs 1zone mainframe, module with 3m power cable
3) 1pcs 5pin J-type mold power-thermocouple
$280.00







DTHRC-B2Bench Top 2-zone hot runner temperature controller1) Power Supply: 220Vac (or 230Vac), 1Phase 4-wire, 50-60Hz
2) 1pcs 2 zone mainframe, module with 3m power cable
3) 1pcs 5pin J-type mold power-thermocouple
$385






DTHRC-ModuleHot Runner Temperature Control Module1) Power Supply: AC85V~265V, 50/60Hz
2) Sensor Type: J, K
3)Temperature Control Type: PID Control or Manual
4)Output Device: Triac 40A/600V
5) Load Capability: 15A / 240Vac; Optional 20A
Normally $140 Special offer only $120 each





DTHRC-2Z2-zone Hot Runner Temperature Controller1) Power Supply: 380Vac (or 415Vac), 3Phase 4-wire, 50-60Hz
2) 1 pcs 2-zone Mainframe with 3m Power Cable
3) 2 pcs Temperature Control Module
4) 1 pcs 4-pair J-type Mold Power-Thermocouple
$776






DTHRC-4Z4-zone Hot Runner Temperature Controller1) Power Supply: 380Vac (or 415Vac), 3Phase 4-wire, 50-60Hz
2) 1 pcs 4-zone Mainframe with 3m Power Cable
3) 4 pcs Temperature Control Module
4) 1 pcs 4-pair J-type Mold Power-Thermocouple
$1,160







DTHRC-6Z6-zone Hot Runner Temperature Controller1) Power Supply: 380Vac (or 415Vac), 3Phase 4-wire, 50-60Hz
2) 1 pcs 6-zone Mainframe with 3m Power Cable
3) 6 pcs Temperature Control Module
4) 1 pcs 6-pair J-type Mold Power-Thermocouple
$1,444






DTHRC-8Z8-zone Hot Runner Temperature Controller1) Power Supply: 380Vac (or 415Vac), 3Phase 4-wire, 50-60Hz
2) 1 pcs 8-zone Mainframe with 3m Power Cable
3) 8 pcs Temperature Control Module
4) 2 pcs 4-pair J-type Mold Power-Thermocouple
$1,848






DTHRC-10Z10-zone Hot Runner Temperature Controller1) Power Supply: 380Vac (or 415Vac), 3Phase 4-wire, 50-60Hz
2) 1 pcs 10-zone Mainframe with 3m Power Cable
3) 10 pcs Temperature Control Module
4) 2 pcs 6-pair J-type Mold Power-Thermocouple
$2128







DTHRC-12Z12-zone Hot Runner Temperature Controller1) Power Supply: 380Vac (or 415Vac), 3Phase 4-wire, 50-60Hz
2) 1 pcs 12-zone Mainframe with 3m Power Cable
3) 12 pcs Temperature Control Module
4) 2 pcs 6-pair J-type Mold Power-Thermocouple
$2,508






DTHRC-24Z24-zone Hot Runner Temperature Controller1) Power Supply: 380Vac (or 415Vac), 3Phase 4-wire, 50-60Hz
2) 1 pcs 24-zone Mainframe with 3m Power Cable
3) 24 pcs Temperature Control Module
4) 4 pcs 6-pair J-type Mold Power-Thermocouple
$5,016






Features and Benefits

  • Compatible Yudo, Athena, DME, PCS, Incoe
  • Dual lines LED Display per module, easy operation
  • Switch freely between auto, manual, and standby functions
  • PID auto temperature control
  • Selectable two thermocouple types (J/K )
  • Selectable two temperature scales (°C /°F)
  • Selectable two trigger output modes (zero cross or phase angle)
  • Multi-diagnostic and alarm function
  • Multi self-protection and equipment-protect function
  • Selectable two start modes (soft-start and full speed)
  • Easily recover factory default parameters

 

 

Diagnostic Functions

  • Alarm when the following occurs:
  • Ultra-high or ultra-low temperature
  • Thermocouple break, short or inverse
  • Thermocouple is out of position
  • Heater break, sort or overload
  • Output device is damaged

 

 

Protection functions

  • Wide power supply range AC85–400V
  • Thermocouple input protection, prevent module damaged by misconnection
  • Thermocouple & heater inverse protection, prevent thermocouple damaged by misconnection
  • Soft-start mode, avoid heater
  • burnout due to moisture
Specifications
Power SupplyAC85 – 265V, 50/60HzWorking TemperatureOutput TypeZero cross / Phase angle
0–50° C
Control ModeAuto-PID / ManualStorage Temperature-20–70° CMeasurement Range0–900°F (0–500°C)
Sensor TypesThermocouple J or KWorking Humidity10–80% RH (non ‑ condensing)Setting Range0–842°F(0–450°C)
Accuracy± 0.25% FSPower Consumption<4.5WLoad Capacity
15A, 3600W @ 240Vac per zone

 

Hot Runner Controls Valve Gate Control Module

 

Features and Benefits

  • Dual lines LED Display, easy operation
  • Auto/Manual functions
  • Selectable output control mode (Mode-0 or Mode-1)
  • Selectable input signal type (DC24V or Switch)
  • Selectable output signal type
  • C220V, DC24V or Relay contact)
  • Multi-diagnostic and alarm function
  • Wide power supply range (AC85–400V)
  • Polarity can be ignored when input signal is DC24V
  • Easily recover factory default parameters
Specifications
Power SupplyAC85 – 400V, 50/60HzWorking TemperatureControl ModeMode-0 or Mode-1
0–50° C
Control ModeAuto / ManualStorage Temperature-20–70° COutput TypeAC220V, DC24V or Relay contact
Input TypeDC24V/SwitchWorking Humidity10–80% RH (non ‑ condensing)Load Capacity
AC220V output: 3A
DC24V output: 3W
Relay contact output: 3A
Time Range0.0–999.99s/0.00–99.99sConsumed Power<3WPower SwitchHRVG-B: Rocker Switch